ST01 Series Thermal Protector Working Principle:

When the circuit is normal, the movable contact is in close contact with the stationary silver contact under the pre-pressure of the spring disc. When the rated operating temperature is reached, the bimetal disc is deformed by heat, snaps into its inverted position and pushes the spring disc downwards. The contact is abruptly opened and the temperature rise of the device to be protected is disrupted.

After the circuit is disconnected, the ambient temperature begins to fall. When it reaches the defined reset temperature, the bimetal disc and the spring disc snaps back into its start position, the movable contact and the stationary silver contact will close again, and the circuit returns to the conduction state.


Technical description

  • Action temperature in 5°C
    1. 60 °C - 180 °C
  • Tolerance (standard)
    1. ±5K
  • Reset temperature & Tolerance
    1. ≥ 35°C (≤ 80°C NST)
      -30K ± 15K (≥ 85°C ≤ 180°C NST)
  • Thickness
    1. 5.6mm
  • Diameter
    1. 9.2mm
  • Resistance to impregnation
    1. suitable
  • Applicable installation protection level
    1. I+ll
  • Pressure resistance to the shell
    1. 300N
  • Standard lead wire
    1. 0.33 mm² / AWG22
  • Insulation & Voltage resistance
    1. 1.5 kV
  • Reaction time
    1. < 1 ms
  • Contact resistance
    1. ≤ 50 mΩ
  • Anti-Vibration performance (10 - 60 Hz)
    1. 100 m/s²
  • Operating voltage range AC/DC
    1. Max. 500 V AC / 28 V DC
  • Rated voltage AC
    1. 250 V
  • Rated current AC cos ϕ = 1.0 /cycles
    1. 2.5 A / 10,000
  • Max. switching current AC cos ϕ = 1.0 /cycles
    1. 6.3 A / 3,000
      7.5 A / 300
  • Rated current AC cos ϕ = 0.6 /cycles
    1. 1.6 A / 10,000
  • Rated direct voltage
    1. 24.0 V
  • Rated DC
    1. 6.0 A

annotation:

The product parameters are provided by Saftty's testing standards, and just for reference. The buyer is responsible for independent analysis, evaluation and judgment during design or use. For the data other than the above parameters, Saftty did not conduct any tests. and Saftty has the right to correct or change the data.
CONTACT US

Sales:Tracy

Phone:

E-mail:sa@saftty.com

icon-d1 icon-d2
LOGIN
REGISTER_ACCOUNT
SAMPLE_REQUEST
  • Application:
  • Model:
  • Type:
  • Operating temperature(℃):
  • Operating voltage(V):
  • Operating current(A):
  • Wire type(UL):
  • Lead wire(AWG):
  • Wire length(mm):
SPECIAL_REQUIREMENTS: