ST06U1
ST06U13
ST06U12
ST06U1
ST06U13
ST06U12

ST06 Series Thermal Protector Working Principle:

When the circuit works normally, the movable contact and the stationary silver contact are in a closed state. When the rated operating temperature is reached, the bimetal disc is deformed by heat, and the spring disc is pushed downward through the riveting shaftpin, so that the movable and stationary silver contact are abruptly opened. 

After the circuit is disconnected, the ambient temperature begins to fall. When it reaches the defined reset temperature, the bimetal disc and the spring disc snaps back into its start position, the contacts will close again, and the circuit returns to the normal working state.

Technical description

  • Action temperature in 5°C
    1. 60 °C - 180 °C
  • Tolerance (standard)
    1. (60-180) °C ± 5K
  • Reset temperature & Tolerance
    1. ≥ 35°C (≤ 95°C NST)
      -50K ± 15K (≥ 100°C ≤ 180°C NST)
  • Thickness
    1. 6.8mm
  • Diameter
    1. 9.5mm
  • Length of the insulation cap
    1. 16mm
  • Resistance to impregnation
    1. suitable
  • Applicable installation protection level
    1. I+ll
  • Pressure resistance to the shell
    1. 600N
  • Standard lead wire
    1. 0.81 mm² / AWG18
  • Anti-Vibration performance (10 - 60 Hz)
    1. 100 m/s²
  • Insulation & Voltage resistance
    1. 2.0 kV
  • Reaction time
    1. < 1 ms
  • Contact resistance
    1. ≤ 50 mΩ
  • Operating voltage range AC/DC
    1. Max. 500 V AC / 28 V DC
  • Rated voltage AC
    1. 250 V
  • Rated current AC cos ϕ = 1.0
    1. 10.0 A
  • Rated current AC cos ϕ = 0.6
    1. 6.3 A
  • Rated direct voltage
    1. 24.0 V
  • Rated DC
    1. 10.0 A