Automotive air conditioning pressure sensor 33SPC-P30B1
3
3

The PC Series pressure sensors are widely applied in various automotive control systems. In automotive air conditioning systems, the sensor measures refrigerant pressure for real-time monitoring by the ECU. In braking systems, it monitors the pressure of the air reservoir in real time. In transmission systems, it is used to measure transmission oil pressure.

The product features a wide operating temperature range, high measurement accuracy, excellent reliability, and long service life. It ensures stable and dependable performance even under harsh environmental conditions.

Technical description

  • Operating Pressure
    1. 0~30 barG (adjustable)
  • Accuracy
    1. ±1.0%FS @25℃
  • Total Error Band
    1. ±2.5%FS (-40℃ ~ +135℃)
  • Operating Temperature
    1. -40℃ ~ +135℃
  • Media Temperature
    1. -40℃ ~ +135℃
  • Storage Temperature
    1. -40℃ ~ +140℃
  • Proof Pressure
    1. 45 barG
  • Burst Pressure
    1. 60 barG
  • Supply Current
    1. ≤10mA
  • Load Impedance
    1. 10 kΩ (typical)
  • Input Voltage
    1. 5 ± 0.25V DC
  • Output Signal
    1. 0.5 ~ 4.5V DC (ratiometric)
  • Response Time
    1. <10ms
  • Insulation Resistance
    1. >100MΩ @500V DC/1min
  • Overvoltage Protection
    1. 20V DC
  • Reverse Voltage
    1. -14V DC
  • Short Circuit Protection
    1. Yes
  • Ingress Protection
    1. IP67
  • Process Medium
    1. Refrigerant
  • Electrical Connector
    1. Packard #12065287
  • Pressure Port
    1. 7/16-20 UNF-2B
  • Housing Material
    1. 6061 Aluminum Alloy

Commenti:

I parametri del prodotto sono forniti dagli standard di collaudo di Saftty e sono forniti a solo scopo di riferimento. L'acquirente è responsabile dell'analisi, della valutazione e del giudizio indipendenti durante la progettazione o l'utilizzo. Per dati diversi dai parametri sopra indicati, Saftty non ha condotto alcun test e si riserva il diritto di correggere o modificare i dati.